INSTALLATION INSTRUCTIONS
SK0-0055-001 HUMIDISTAT
The humidistat is designed for
either return air duct or wall
mounting
. Packaged in a duct mount configuration,
(For this type
mounting begin installation at the section labeled return air duct
installation on page 2.)
for conversion to a wall mount configuration
simply pull off the knob and remove the mounting screws and rotate the
control 180° and reattach the mounting base, (For this type mounting
begin installation at the section labeled wall mount installation on
page 3.)
.
DANGER
Do not cut or drill any air-conditioning or electrical
accessories during installation.
Fatal electrocution is possible if you contact a live wire.
Electrical power can cause electrical shock
Disconnect all electrical power supplied to the equipment
before beginning installation.
Blindness can occur if freon contacts your eyes.
CAUTION
Do not install on any electrical system over 30 VAC
CAUTION
All electrical wiring should comply with codes and
ordinances.
At Outside Temperatures Recommended Setting
-20°F -30°C 15%
-10°F -25°C 20%
0°F -20°C 25%
+10°F -10°C 30%
+20°F -5°C 35%
Over 20°F Over 0°C 40%
Recommended Settings
Warning:
Adjusting the
humidity control
higher than the rec-
ommended setting
may cause conden-
sation resulting in
possible damage to
the
home.
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - INSTALLATION INSTRUCTIONS

Page 1 INSTALLATION INSTRUCTIONS SK0-0055-001 HUMIDISTAT The humidistat is designed for either return air duct or wall mounting. Packaged in a duct mo

Seite 2 - RETURN AIR DUCT INSTALLATION

Page 2 RETURN AIR DUCT INSTALLATION 1 Locate the humidistat in the return air duct at least 12 in. up stream prior to the humidifier or the humidifier

Seite 3 - WALL MOUNT INSTALLATION

Page 3 WALL MOUNT INSTALLATION 1 Locate the humidistat about 5 ft. above the floor, on an inside wall, away from discharge registers. Also, avoid are

Seite 4 - WIRING INSTRUCTIONS

Page 4 WIRING INSTRUCTIONS CAUTION: ∗ Use the wiring diagram shown for single speed blower operation only. ∗When wiring multispeed blower systems u

Kommentare zu diesen Handbüchern

Keine Kommentare